After an upgrade migration of all apps did not work. Migration service unable to start.
Article Number: 000077845 | Last Modified: 2019/06/28
Description
Environment: Qlik Sense
Upon investigating the app migration service logs (found in C:\ProgramData\Qlik\Sense\Logs\AppMigration) we find the repeated error:
5 20190529T135847.281+0200 servername 4.8.2 Request INFO Request 0 will be sent: https://servername:4242/qrs/servernodeconfiguration/full (GET), payload: <no payload> 6 20190529T135847.286+0200 servername 4.8.2 Global WARN Repository configuration not available, re-trying in 1 second(s)...: error:0B080074:x509 certificate routines:X509_check_private_key:key values mismatch
Cause
Somehow the locally copies of the certificate used by some services no longer match those found in the certificate store.
These are automatically re-exported upon service start, so we delete the mismatching certificates, restart the services and let the system clear the problem itself.