When changing the script
C:/Windows/System32/config/AppData/Roaming/QlikTech/Setting.ini file. The following error is seen
"Error 1067: The process terminated unexpectedly. The process terminated unexpectedly"Following the instruction posted on
QlikView 12: Distribution Service is not generating document log until reload completionOne more row 'LocalScriptLogging=' in .
settings.ini file was added.
The below services were disabled.
Qlikview Directory Service Connector stopped
Qlikview Distribution Service Stopped
Qlikview Management Service Stopped
Qlikview Webserver Stopped
Enviornment:
Distribution Service is not generating document log until reload completes.
Since QlikView 12 SR1, the document reload log is generated locally on the QlikView Distribution Serrvice node handling the reload task inside
C:\ProgramData\QlikTech\QlikViewBatch Once the reload is done, the document log is then copied to the Source Document folder and QDS Application Data folder.
The purpose of this change is to avoid continuously writing log entries to remote folders.
This change is documented in the Release Notes for QlikView 12 SR1, which is available on our download site.