Environments:
- NPrinting all versions 17
- NPrinting all versions 18
After NPrinting upgrade, none of the task is running, cache connection can't be generated.
When upgrade on NPrinting 17/18 is performed, all components must be on same version
Performed upgrade on Server component: QlikNPrintingServer_x64 (ver 18.9.5.0):
- NPrinting DB (ver. 18.9.5.0)2018-05-08 12:13:59,068 [1] INFO Qlik.NPrinting.Repo.UpgradeDb.NPrinting17UpgradeHelper - Qlik.NPrinting.Repo.UpgradeDb 18.9.5.0 Qlik.NPrinting.Repo.UpgradeDb.NPrinting17UpgradeHelper 20180508T121359.068+00:00 INFO NPRINTING 0 0 0 0 0 0 0 0 Database successfully upgraded to version 18.9.5.0.
- Scheduler (ver. 18.9.5.0) Qlik.NPrinting.Scheduler 18.9.5.0 Qlik.NPrinting.Scheduler.SchedulerHttpService 20180508T121401.782+00:00 INFO NPRINTING 0 0 0 0 0 0 0 0 Starting up scheduler service
- WebEngine (ver. 18.9.5.0) Qlik.NPrinting.WebEngine 18.9.5.0 Qlik.NPrinting.WebEngine.Engine 20180508T121359.652+00:00 INFO NPRINTING 0 0 0 0 0 0 0 0 The service is starting
NOT performed upgrade on Engine component: QlikNPrintingEngine_x64 (17.6.0.0)
- Unexpected socket error: 10053
Caller: OnStreamEndRead, file path: d:\WorkShop\SuperSocket\v1.6\SocketEngine\AsyncStreamSocketSession.cs, line number: 162
The server instance QlikSensePrintingWebSocketProxy has been stopped!
Qlik.NPrinting.Engine 17.6.0.0 Qlik.NPrinting.Engine.EngineService 20180508T095151.734+00:00 INFO NPRINTING 0 0 0 0 0 0 0 0 Engine service stopped
Upgrade Engine component is resolving the issue