Join UsThis behavior is due to a new entry in the Settings.ini file introduced to improve performance that suppresses the drawing of the values when > 1000
The value can be adjusted to the max values expected.
The Default location for Settings.ini : C:\ProgramData\QlikTech\QlikViewServer
Please make sure to stop the QlikVIew server service on all servers in the QlikView cluster
Make a backup copy of the settings.ini on each server in the cluster
Add or modify ChartLegendCutoff=1000 to the number of values required
Save the settings.ini
Restart the Qlikview services on all servers in the QlikView cluster
Settings.ini location for desktop: C:\Users\<User>\AppData\Roaming\QlikTech\QlikView\Settings.ini