Qlik Sense Enterprise Management Console Shows 1 Of 1 Services Running Instead Of 5 of 5 Services

No ratings
cancel
Showing results for 
Search instead for 
Did you mean: 
Daniel_Seo
Support
Support

Qlik Sense Enterprise Management Console Shows 1 Of 1 Services Running Instead Of 5 of 5 Services

Last Update:

Jul 13, 2021 9:03:37 AM

Updated By:

Sonja_Bauernfeind

Created date:

Feb 1, 2020 10:27:02 PM

The Qlik Sense Management Console (QMC) displays the wrong Status of services running.

5 of 5 Services are running in the Central node and Rim node. However, QMC shows 1 of 1 services running instead of 5 of 5 services.

 

Environment:

Qlik Sense Enterprise on Windows 

 

This is caused by a resync issue between the Windows Server and Storage such as due to a disconnect or cluster failover. 

 

Resolution:


Root cause:

Resync issue happened between Windows Server and Storage from some reason (disconnection/Network/cluster Failover.)

This mean that Storage volume was detached and attached from Windows Server in a very short time as Failover happened successfully.

As a result, Windows Server has still old disk volume image and Qlik Sense doesn't know it because there was no transaction or disk IO in the same disk volume image.

https://docs.microsoft.com/en-us/windows-server/storage/storage-spaces/understand-storage-resync


Solutions:

In order to establish resync correctly among Storage volume image, Windows and Qlik Sense services, It need to restart Qlik Sense services and reboot Windows OS after Resync issue or failover happened.

Or execute Storage resync command in Windows Server (It depends on Storage vendor)